4. SCON-CA

159

[2] Position/simple direct mode: In this mode, the actuator is operated by specifying position numbers.

You can select whether to specify the target position directly as a value, or

use a value registered in the position data table, by switching a control

signal.

For the speed, acceleration/deceleration, positioning band, etc., values

preregistered in the position data table are used. Up to 768 position data

points can be set.

Number of occupied bytes: 8 bytes

Target position: 100.00 mm

+

Position No. 0

SCON-CA supporting

EtherNet/IP

Actuator

Speed

Acceleration

Push

Deceleration

[3] Half direct mode:

In this mode, the actuator is operated by specifying the speed,

acceleration/deceleration and pressing current, in addition to the target position,

directly as values.

Number of occupied bytes: 16 bytes

SCON-CA supporting

EtherNet/IP

Actuator

Target position: 100.00 mm

Positioning band: 0.10 mm

Speed specification:

100.0 mm/sec

Acceleration/deceleration:

0.30 G

Pressing current: 50%