beautypg.com

IAI America PCON-CFA User Manual

Page 222

background image

4. SCON-CA

214

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal type Bit Symbol

Contents

Details

Pressing

current-

limiting

value

16-bit

data

-

16-bit integer

Specify the current-limiting value to be used during pressing

operation.

The allowable specification range is 0 (0%) to 255 (100%).

The actual settable range varies depending on each actuator.(Refer

to the catalog or Operation Manual for the actuator.) If a move

command is issued by specifying a value exceeding the maximum

pressing current, an alarm will occur.

4.8 (2)

b15 BKRL Forced brake release: When it is turned ON, the brake is released.

4.6.11 (18)

b14 RMOD

Operating mode selector: The AUTO mode is selected when this

signal is OFF, and the MANU mode is selected when the signal is

ON.

4.6.11 (19)

b13 DIR

Pressing direction specification:

“OFF” for the direction reducing the positioning band from the target

position,

“ON” for the direction adding the positioning band to the target

position

4.6.11 (22)

b12 PUSH

Pressing specification: Positioning operation is performed when this

signal is OFF, and pressing operation is performed when the signal is

ON.

4.6.11 (21)

b11
b10

-

Unavailable

-

b9 CLBR Load cell calibration command: Calibration is performed when this

signal turns ON.

4.6.11 (32)

b8 JOG+ + Jog: “ON” for Movement in the Opposite Direction of Home

4.6.11 (13)

b7 JOG- -Jog: “ON” for Movement to the Home Direction

4.6.11 (13)

b6 JVEL

Jog-speed/inch-distance switching:

The values set in parameter No. 26, “Jog speed” and parameter No.

48, “Inch distance” are used when this signal is OFF, and the values

set in parameter No. 47, “Jog speed 2” and parameter No. 49, “Inch

distance 2” are used when the signal is ON.

4.6.11 (14)

b5

JISL

Jog/inch switching:

Jog operation is performed when this signal is OFF, and inch

operation is performed when the signal is ON.

4.6.11 (15)

b4 SON Servo ON Command: The servo turns ON when this signal turns ON. 4.6.11 (5)
b3

RES Reset: A reset is performed when this signal turns ON.

4.6.11 (4)

b2

STP Pause: A pause command is issued when this signal turns ON.

4.6.11 (11)

b1 HOME Home return: A home-return command is issued when this signal

turns ON.

4.6.11 (6)

P

LC

o

ut

pu

t

Control

signal

b0 DSTR Positioning Command: A move command is issued when this signal

turns ON.

4.6.11 (8)

This manual is related to the following products: