3. SCON-CA/CF

A

110

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal type

Bit Symbol

Contents

Details

Current

position

32-bit

data

-

32-bit signed integer indicating the current position

The setting unit is 0.01mm.

(Example) Reading:

000003FF

H

=1023 (decimal)

=10.23mm

* When the value is read in hexadecimal notation, the negative figure is

expressed as a complement of 2.

3.8 (2)

Command

current

32-bit

data

-

32-bit integer

The electrical current presently specified by a command is indicated.

The setting unit is mA.

(Example) Reading:

000003FF

H

=1023 (decimal)

=1023mA

3.8 (2)

Current

speed

32-bit

data

-

32-bit signed integer indicating the current position

The current speed is indicated.

Positive value: The actuator is moving in the direction opposite home.

Negative value: The actuator is moving in the direction of home.

The setting unit is 0.01mm/sec.

(Example) Reading: 000003FF

H

=1023 (decimal)

=10.23mm/sec

* When the value is read in hexadecimal notation, the negative figure is

expressed as a complement of 2.

3.8 (2)

Alarm code 16-bit

data

-

16-bit integer

When an alarm is issued, the alarm code is output.

When any alarm is not issued, it is “0

H

”.

Refer to the operation manual for the controller main body for the details

of the alarms.

3.8 (2)

b15 EMGS

Emergency stop: An emergency stop is actuated when this signal turns

ON.

3.6.7 (2)

b14

PWR

Controller ready: This signal turns ON when the controller becomes ready.

3.6.7 (1)

b13 ZONE2

Zone 2: “ON” for the current position within the zone set range

3.6.7 (12)

b12 ZONE1

Zone 1: “ON” for the current position within the zone set range

3.6.7 (12)

b11
b10

b9

-

Unavailable

-

b8

RMDS

Operation mode status:

This signal is OFF when the current mode is AUTO, or ON when the

current mode is MANU.

3.6.7 (19)

b7

ALML

Light error status:

Turns ON when light alarm (threshold exceeded for number of

movement, etc.) that the operation can be continued with is issued.

Note: ALM LED would not turn ON with a light error.

3.6.7 (31)

b6

-

Unavailable

-

b5

PSEL

Pressing and a Miss: This signal turns ON when the actuator missed the

work part in pressing operation.

3.6.7 (23)

b4

SV

Operation preparation end: This signal turns ON when the servo turns

ON.

3.6.7 (5)

b3

ALM

Alarm: This signal turns ON when an alarm occurs.

3.6.7 (3)

b2

MOVE

Moving signal: This signal remains ON while the actuator is moving.

3.6.7 (9)

b1

HEND

Home return completion: This signal turns ON when home return is

completed.

3.6.7 (6)

P

LC

in

pu

t

Status

signal

b0

PEND

Positioning completion signal: This signal turns ON when positioning is

completed.

3.6.7

(10)