ACON-C/CG, PCON-C/CG

80

z

Network type (No.87 NTYP)

The network module type is set for the parameter No. 87. Do not change the default value.

z

Field I/O format (No.90 FMIO)

Addresses in the PLC are assigned in units of 16 points (2 bytes) based on the node address set in the

controller and the occupied bytes in each operation mode.

By changing the setting of parameter No. 90, data elements can be swapped within a boundary of two

words or less in units of bytes during communication using the I/O areas of the PLC.

Value set in

parameter No. 90

Contents

0

Data exchange is not performed. The data is sent directly to the PLC.

(Refer to “Example i”.)

1

The host bytes are exchanged with slave bytes in the host words and

slave words. (Refer to “Example ii”.)

2

In the case of word register, the host words are exchanged with the

slave words.

(Refer to “Example iii”.)

3 (Factory setting)

The host bytes are exchanged with slave bytes in the host words and

slave words. In addition, the upper word and lower word are swapped

for word resisters. (Refer to “Example iv”.)

(Example i) Set value = “0”

z

indicates ON, while c indicates OFF

ACON,

PCON

Input

resister

Hexadecimal

data

Hexadecimal

data

PLC:

Output

CH

ACON,

PCON

Output

resister

Hexadecimal

data

Hexadecimal

data

PLC:

Input CH