Using the teaching tool, set controller parameters. Set the mode toggle switch on the front panel of the

controller to “MANU” side. The versions of teaching tool compatible with EtherNet/IP are as follows:

x

RC PC-compatible software: V8.01.01.00 or later

x

CON-T/TG:

V1.10 (Planned)

x

CON-PT/PD/PG:

V1.20 (Planned)

x

RCM-E/P:

V2.20 (Planned)

4.5.1

Operation Mode Selecting

Set parameter No. 84 “FMOD: Field bus operation mode.”

[Refer to 4.9 EtherNet/IP Related Parameters.]

Set value

Operation mode

Number of

occupied bytes

0 (Factory setting)

Remote I/O mode

2

1

Position / Simplified direct value mode

8

2

Half direct value mode

16

3

Full direct value mode

32

4

Remote I/O mode

12

5

Position / Simplified direct value mode2

8

6

Half direct value mode 2

16

7

Remote I/O mode 3

12

8

Half direct value mode 3

16

* Entering any value except for the ones described above will cause an “Excessive Input Value Error”.

4.5.2

Setting the Baud Rate

Set parameter No. 86, “FBRS: Fieldbus baud rate.”

Set value

Baud rate

0 (Factory setting)

Auto negotiation (recommended)

1

10 Mbps, half-duplex

2

10 Mbps, full-duplex

3

100 Mbps, half-duplex

4

100 Mbps, full-duplex

Other than the above

Baud rate setting error