(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal type

Bit Symbol

Contents

Details

Current

position

32-bit

data

-

32-bit signed integer indicating the current position

The setting unit is 0.01mm.

(Example) Reading: 000003FF

H

=1023 (decimal)

=10.23mm

* When the value is read in hexadecimal notation, the negative figure is

expressed as a complement of 2.

4.8 (2)

Command

current

32-bit

data

-

32-bit integer

The electrical current presently specified by a command is indicated.

The setting unit is mA.

(Example) Reading: 000003FF

H

=1023 (decimal)

=1023mA

4.8 (2)

Current

speed

32-bit

data

-

32-bit signed integer indicating the current position

The current speed is indicated.

Positive value: The actuator is moving in the direction opposite home.

Negative value: The actuator is moving in the direction of home.

The setting unit is 0.01mm/sec.

(Example) Reading: 000003FF

H

=1023 (decimal)

=10.23mm/sec

* When the value is read in hexadecimal notation, the negative figu

re is

expressed as a complement of 2.

4.8 (2)

Alarm code 16-bit

data

-

16-bit integer

When an alarm is issued, the alarm code is output.

When any alarm is not issued, it is “0H”.

Refer to the Operation Manual for the controller main body for the details of

the alarms.

4.8 (2)

b15 EMGS Emergency stop: An emergency stop is actuated when this signal turns

ON.

4.6.11 (2)

b14 PWR Controller ready : This signal turns ON when the controller becomes ready. 4.6.11 (1)
b13 ZONE2 Zone 2:“ON” for the current position within the zone set range

4.6.11 (12)

b12 ZONE1 Zone 1:“ON” for the current position within the zone set range

4.6.11 (12)

b11
b10

-

Unavailable

-

b9 CEND Load cell calibration is complete: This signal turns ON when calibration is

complete.

4.6.11 (32)

b8 RMDS

Operation Mode Status:

This signal is OFF when the current mode is AUTO, or ON when the

current mode is MANU.

4.6.11 (19)

b7 BALM Absolute battery voltage low warning: This signal turns ON when the

voltage drops

4.6.11 (28)

b6 PUSHS Pressing operation in progress: The signal is ON when the Pressing

operation in progress.

4.6.11 (25)

b5 PSEL Pressing and a Miss: This signal turns ON when the actuator missed the

work part in pressing operation.

4.6.11 (23)

b4

SV Operation preparation end: This signal turns ON when the servo turns ON. 4.6.11 (5)

b3

ALM Alarm: This signal turns ON when an alarm occurs.

4.6.11 (3)

b2 MOVE Moving Signal: This signal remains ON while the actuator is moving.

4.6.11 (9)

b1 HEND Home return completion: This signal turns ON when home return is

completed.

4.6.11 (6)

PLC

input

Status

signal

b0 PEND Positioning completion signal: This signal turns ON when positioning is

completed.

4.6.11 (10)