4. SCON-CA

186

(3) I/O signal assignment (* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal type

Bit

Symbol

Contents

Details

Target

position

32-bit

data

-

32-bit signed Integer.

Set the target position on the absolute coordinates.

The unit is 0.01mm and settable range is between –999999 to

+999999.

(Example) When it is “+25.41mm”, set it as “2541”.

If the value larger than the value (0.2mm) inside the soft limit

for the parameter, the movement would be limited to the

inside the soft limit (0.2mm).

* When the input is performed in hexadecimal notation, input

the negative value using a complement of 2.

4.8 (2)

Positioning

band

32-bit

data

-

32-bit integer

The unit is 0.01mm and settable range is between 1 to

+999999.

(Example) When it is “25.40mm”, set it as “2540”. This register

value has two meanings depending on the operation type.

1) In the case of positioning operation, it shows the allowable

range from the target position, that is regarded as the

positioning completion.

2) In the case of pressing operation, it shows the pressing

width value. Specify the normal operation or pressing

operation using the “PUSH” control signal setting.

4.8 (2)

Speed

16-bit

data

-

16-bit integer.

Specify the speed at which to move the actuator.

Designate the unit of 1.0mm/sec or 0.1mm/sec.

The settable range is 0 to 65535.

Unit of measure is selected by Parameter No. 159 FB Half

Direct Mode Speed Unit.

(Example) In the case of the unit of 1.0mm/sec:

To set 254.0 mm/sec, specify “254.”

If a move command is issued by specifying a value exceeding

the maximum speed, an alarm will occur.

4.8 (2)

P

LC

o

ut

pu

t

Acceleration/

deceleration

16-bit

data

-

16-bit integer

Specify the acceleration / deceleration at which to move the

actuator (the acceleration and deceleration will be the same

value).

The unit is 0.01G and settable range is 1 to 300.

(Example) To set “0.30 G”, specify “30”.

If a move command is issued by specifying “0” or any value

exceeding the maximum acceleration or deceleration, an

alarm will occur.

4.8 (2)