EtherNet/IP Related Parameters

Parameters relating to EtherNet/IP are No. 84, No. 86 to 87, No. 90, No. 140 to 142 and No. 159.

Category: C: External interface parameter

No. Category

Symbol

Name

Default value set in the

factory before delivery

1

~

83

Refer to operation manual for the

controller for the parameters No. 1

through No. 83.

84

C

FMOD

Field bus operation mode

0

86

C

FBRS

Field bus baud rate

0

87

C

NTYP

Network type

7

90

C

FMIO

Field I/O format

3

140

C

IPAD

IP address

192.168.0.1

141

C

SNMK

Subnet mask

255.255.255.0

142

C

DFGW

Default gateway

0.0.0.0

159

C

FBVS

FB Half Direct Mode Speed Unit

0

z

Field bus operation mode (No.84 FMOD)

Specify the operation mode in parameter No. 84 using a value between 0 and 4.

Value set in

parameter No. 84

Mode

Number of

occupied bytes

Contents

0

(Factory setting)

Remote I/O mode

2

Operation using PIOs

(24 V I/Os) is performed via EtherNet/IP.

1

Position/simple

direct mode

8

The target position can be set directly using

the value or the operation can be

performed using position data value.

The other values required for the operation

are set on the position data.

2

Half direct value

mode

16

In addition to the target position, the speed,

acceleration/deceleration and pressing

current value are set directly using the

values to perform the operation.

3

Full direct value

mode

32

All the values related to the position control

are set using the values to perform the

operation.

4

Remote I/O mode

2

12

The current position and current speed

reading functions are added to the

functions in the remote I/O mode.

z

Fieldbus baud rate (No. 86: FBRS)

Specify the baud rate in parameter No. 86.

Set value

Baud rate

0 (Factory setting)

Auto negotiation (recommended)

1

10 Mbps, half-duplex

2

10 Mbps, full-duplex

3

100 Mbps, half-duplex

4

100 Mbps, full-duplex

Other than the above

Baud rate setting error