4.10 Troubleshooting

z

Alarm messages and causes/actions

When an alarm occurs, a corresponding simple alarm code is indicated by the completed position number

bits (four bits of PM1 to PM8) in remote I/O mode 1, 2 or 3.

In position/simple direct mode 1 or 2, this simple alarm code is output to the (n+4, n+5) bytes.

In half direct mode 1, 2 or 3 or in the full direct mode, this alarm code is output to the (n+12, n+13) bytes

[1] Check the alarm code using the monitor function of the PLC, etc., or connect the RC PC software or

other teaching tool and check the status monitor screen.

[2] Search the alarm list in the operation manual for your controller to find the section corresponding to

the identified alarm code.

[3] Take an appropriate action according to the explanation of the alarm code.

For the alarm codes listed below, take the corresponding actions:

Code

Error name

ID

(*1)

RES

(*2)

Cause/action

0F2

Fieldbus module error

05

x

Cause: A fieldbus module error has been

detected.

Action: Check the applicable parameters.

0F3

Fieldbus module

non-detection error

04

x

Cause: The module could not be detected.

Action: Reconnect the power. If the problem

persists, please contact IAI.

(*1) ID o Simple alarm code
(*2) RES o Alarm can/cannot be reset – O: Alarm can be reset / X: Alarm cannot be reset