Page 159

background image

3. SCON-CA/CF

A

151

[1]

[2]

[3]

Actuator speed

Speed n2

Speed n3

Set value of speed or

acceleration/deceleration

(4) Data change during movement

In the half direct mode or full direct mode, the value currently set to a given resister among the resisters for

target position data, acceleration/deceleration data, speed data, positioning band and pressing

current-limiting value, can be changed while the actuator is moving.

After changing the data, turn “ON” the positioning command (DSTR) for more than tdpf.

Also, after turning “OFF” the DSTR, set aside some time for “twcsON + twcsOFF” or more, until the next

DSTR is turned “ON”.

The example is shows as follows, where the speed and acceleration/deceleration data items have been

changed.

twcsON • Yt+Xt+3 (msec)

twcsOFF • Yt+Xt+3 (msec)

*Yt+Xt ” tpdf ” Yt+Xt+3 (msec)

Caution

1. When the speed has not been set or it is set to “0”, the actuator is not moved, but an alarm

is not issued.

2. When the speed setting is changed to “0” during the movement, the actuator is

decelerated and stopped, but an alarm is not issued.

3. Even when the acceleration/deceleration data only is changed during the movement, the

setting of the target position data is required.

4. Even when the target position data only is changed during the movement, the setting of

the acceleration/deceleration data is required.

(PLC o PCON)

(PLC o PCON)

(PCON oPLC)

(PCON oPLC)