2.

ACON-C/CG, PCON-C/CG

52

(3) I/O signal assignment

For the signal assignments corresponding to each PIO pattern, refer to the I/O signal assignments for the

remote I/O mode explained in 2.6.2 (3).

The signal allocation for the Command current and Current position is shown in the following table.

Signal type

Bit

Symbol

Contents

Details

Current

position

32-bit data

-

32-bit signed integer indicating the current position

The setting unit is 0.01mm.

(Example) Reading:000003FF

H

=1023 (decimal)

=10.23mm

* When the value is read in hexadecimal notation, the

negative figure is expressed as a complement of 2.

-

P

LC

in

pu

t

Command

current

32-bit data

-

32-bit integer

The value of electrical current specified by the current

command is indicated.

The setting unit is 1mA.

(Example) Reading:000003FF

H

=1023 (decimal)

=1023mA

-