B&K Precision 9171-9174 - Manual User Manual
Page 88

76
2. Go down to
EXTERN CONTROL (this option is only
available with DIO/Analog Card installed) and press
or
to select between
OFF, VOLT, or RES. Select VOLT
for external voltage control or
RES for external resistance
control. Select
OFF to disable external analog control.
3. Press to save the change. If
VOLT is selected in the
previous step, go to
EXTERN LEVEL setting right below
EXTERN CONTROL and press
or
to select
between
5V or 10V. Selecting 5V means a 0 – 5V source
will be used to control the full range of the voltage/current.
Similarly,
10V means a 0 – 10V source will be used.
4. Press again to save the change, and press twice
to go to the main screen, which will look like the following
below (Note that voltage and current resolution will be 10 mV
and 10 mA for external analog control):
For Dual Channel models:
OFF
0.00 V 0.00 A
Enter
Enter
Esc