B&K Precision 9171-9174 - Manual User Manual
Page 131

119
SYStem:EXTernal
Description:
Configure/Query the state/type of the analog external
control.
Syntax:
SYStem:EXTernal
SYStem:EXTernal?
Example:
SYS:EXT 1
SYS:EXT VOLT
Set to use voltage source for external analog control
Query:
SYS:EXT?
Return String:
2
Currently set to resistance external control.
Format:
SYStem:EXTernal:LEVel
Description:
Configure/Query voltage scale to use for external
voltage control.
Syntax:
SYStem:EXTernal:LEVel
SYStem:EXTernal:LEVel?
Example:
SYS:EXT:LEV V10
SYS:EXT:LEV 0
Selects 0-10 V scale to use for external voltage control.
Query:
SYS:EXT?
Return String:
0
0-10 V scale is selected.
Format:
SYStem:GPIB:ADDRess
Description:
Configure/Query the GPIB address.
Syntax:
SYStem:GPIB:ADDRess
SYStem:GPIB:ADDRess?
- 1 – 30 are valid numbers.
Example:
SYS:GPIB:ADDR 6
Sets the GPIB address to 6.
Query:
SYS:GPIB:ADDR?
Return String:
6
Format: