Timer subsystem – B&K Precision 9171-9174 - Manual User Manual
Page 135

123
SYStem:TRACK
Note:
For dual channel models only.
Description:
Configures/Queries the state of tracking mode.
Syntax:
SYStem:TRACK
SYStem:TRACK?
Example:
SYS:TRACK 1
SYS:TRACK ON
Enables tracking mode.
Query:
SYS:TRACK?
Return String:
ON
Format:
ON or OFF
Timer Subsystem
TIMER
Description:
Configures/Queries the state of the output timer
function. The timer starts once output is enabled.
Syntax:
TIMER
TIMER?
Example:
TIMER ON
TIMER 1
Enables timer output.
Query:
TIMER?
Return String:
ON
Format:
ON or OFF
TIMER:HOUR
Description:
Configures/Queries the output timer hours.
Syntax:
TIMER:HOUR
TIMER:HOUR?
Example:
TIMER:HOUR 100
Sets the output timer to 100 hours.
Query:
TIMER:HOUR?
Return String:
100