beautypg.com

B&K Precision 9171-9174 - Manual User Manual

Page 156

background image

144

Description:

Configures/Queries the over voltage protection value of

the selected power supply. See

OVSET/OVSET2

command for similar syntax.

COV2 is for dual channel

models only.

Example:

COV 70.000

Sets the selected power supply’s OVP value to

70.000V.

COV2?

Queries the selected power supply’s second channel

OVP value.

COVP/COVP2

Description:

Configures/Queries the over voltage protection state of

the selected power supply. See

OVP/OVP2 command

for similar syntax.

COVP2 is for dual channel models

only.

Example:

COVP ON

Sets the selected power supply’s OVP state to ON.

COVP2?

Queries the selected power supply’s second channel

OVP state.

COC/COC2

Description:

Configures/Queries the over current protection value of

the selected power supply. See

OISET/OISET2

command for similar syntax.

COC2 is for dual channel

models only.

Example:

COC 3.000

Sets the selected power supply’s OCP value to 3.000 A.

COC2?

Queries the selected power supply’s second channel

OCP value.

COCP/COCP2