beautypg.com

B&K Precision 9171-9174 - Manual User Manual

Page 168

background image

156

Programming and Readback Accuracy ±(% output+offset)

Voltage

0.05%+5mV(9171,9173,9181, 9182)

0.05%+10mV(9172,9174,9183)

0.05%+50 mV(9184)

0.05%+100mV(9185)

Current

0.1%+2mA (9171,9173,9181,9183)

0.1%+1mA (9172,9174,9184)

0.1%+5 mA (9182)

0.1%+0.1 mA (9185)

Temperature Coefficient per °C ±(% output+offset)

Voltage

0.005%+1mV

0.005%+10 mV (9184)

0.005 %+20 mV (9185)

Current

0.01%+3mA

Stability (8 hrs) ±(% output+offset)

Voltage

0.02%+2mV

0.02 %+10 mV(9184)

0.02%+20 mV(9185)

Current

0.1%+1mA

Settling Time

2

30ms

Measurement Time

50ms

Transient Response Time

3

50μs (9171 - 9183)

100μs (9184, 9185)

OVP Accuracy

0.5%+0.1V (9171 – 9183)

0.5%+1V (9184, 9185)

OCP Accuracy

0.5%+0.1A

OVP/OCP Activation Time

4

≤ 1mS

Remote Sense
Compensation

1V Max

Rising Time at Full Load

8mS (9171,9173,9181,9182)

10mS (9172,9174,9183)