beautypg.com

B&K Precision 9171-9174 - Manual User Manual

Page 120

background image

108

PROGram:CLEar:ALL

Description:

Clears all programmed sequences stored in all 10

program locations.

Syntax:

PROGram:CLEar:ALL

Example:

PROG:CLE:ALL

Clears all the programmed sequences in all 10 program

locations.


PROGram:NEXT

Description:

Configures/Queries the next program location’s

sequence to run.

Syntax:

PROGram:NEXT

PROGram:NEXT?

- 1 – 10 are valid program locations. Use 0

to end if no further sequences will be run after the

current sequence.

Example:

PROG:NEXT 5

Runs the set of sequences in program location 5 after

the current sequence is finished.

Query:

PROG:NEXT?

Return String:

3

Currently configured to run sequence in program

location 3 after current sequence ends.

Format:


PROGram:REPeat

Description:

Configures/Queries the number of times to repeat the

selected programmed sequence.

Syntax:

PROGram:REPeat

PROGram:REPeat?

- 1 – 50000 (max.)

Example:

PROG:REP 10

Runs the set of sequences in the selected program

location 10 times.

Query:

PROG:REP?

Return String:

300

Currently set to repeat the sequence 300 times.

Format:


This manual is related to the following products: