beautypg.com

B&K Precision 9171-9174 - Manual User Manual

Page 34

background image

22

WARNING:

DO NOT output 10 A or more with only one pair of

(+) and (-) terminals. Both (+) and (-) terminals

must all be connected for applications requiring

more than 10 A output. Each terminal can only

accept a maximum of 10 A. Exceeding this may

damage the power supply.

Table 2- Wire Gauge Rating

AWG

10

12

14

16

18 20

22

24

26

28

Imax(A)

40

25

20

13

10 7

5

3.5

2.5

1.7

mΩ/meter 3.3

5.2 8.3 13.2 21 33.5 52.8 84.3 133.9 212.9

Rear Panel Output

+S + + - - - S

DUT

+ -

+S + - -S

Remove shorting bars

Front Panel Output

For 10 A or higher current output