beautypg.com

B&K Precision 9171-9174 - Manual User Manual

Page 159

background image

147

GRST

Description:

Resets all the power supplies connected in the chain to

a known state.

Syntax:

GRST


GCLS

Description:

Clears the status of all the power supplies connected in

the chain.

Syntax:

GCLS


GCLR

Description:

Clears the protection flag/trip of all the power supplies

connected in the chain.

Syntax:

GCLR

GPV/GPV2

Description:

Configures/Queries the VSET voltage setting of all the

power supplies connected in the chain. See

VOLTage/VOLT2 command for similar syntax. GPV2 is

for dual channel models only.

Example:

GPV 15.698

Sets all the power supplies’ VSET voltage setting to

15.698 V.


GPC/GPC2

Description:

Configures/Queries the ISET current setting of all the

power supplies connected in the chain. See

CURRent/CURR2 command for similar syntax. GPC2

is for dual channel models only.

Example:

GPC 3.123

Sets all the power supplies’ ISET current setting to

3.123 A.