Enable both channels’ output for a dual channel supply with
address 2

CADR 2
COUTA ON
Return String: OK
-

Query the measured/readback current output of power
supply with address 6

CADR 6
CMC?

Synchronous Control Command


This set of commands can be used to control all the power supplies
connected in the RS-485 chain at once. Note that these commands
will not return an “

OK” string upon making a configuration.


GRST

GCLS

GCLR

GPV/GPV2

GPC/GPC2

GOUT/GOUT2

GOUTA

GOV/GOV2

GOVP/GOVP2

GOC/GOC2

GOCP/GOCP2