71

for setting the power on state to last known configuration.
Select

OFF to turn it off.

2. Press to confirm the change.

3.11

Sequence Program Mode

Up to 10 (1 – 10) programmed sequences can be stored into the
internal memory of the power supply and be executed from the front
panel or via remote commands. A sequence consists of various
steps of voltage and current values with a user defined time to hold
at each step. This allows the user to change the voltage and current
output of the power supply at different timings in a sequence.

The

maximum number of steps per sequence is 150, and the
minimum timing in between steps is 10 ms. For dual channel
models, the programmed sequence will control both channels
per every step. Programming a sequence for each channel
independently is not supported.


Sequences must be programmed into the memory via remote
interface (i.e. USB, GPIB, Ethernet) before it can be executed from
the front panel. See “4 Remote Operation” for details.

Assuming that sequences are already programmed into the internal
memory, follow these steps to execute a program.

1. Press , then to enter

PROGRAM MODE. The

following screen will be displayed:

Menu

5

Enter

This manual is related to the following products: