B&K Precision 9171-9174 - Manual User Manual
Page 169

157
≤
30mS (9184)
≤
40mS (9185)
Rising Time at No Load
≤
8mS (9171,9173,9181,9182)
≤
10mS (9172,9174,9183)
≤
30mS (9184)
≤
40mS (9185)
Falling Time at Full Load
≤
8mS (9171,9173,9181,9182)
≤
10mS (9172,9174,9183)
≤
30mS (9184)
≤
40mS (9185)
Falling Time at No Load ≤ 250mS
Standard Interface
USB
Optional Interface Cards
5
LAN/GPIB Card, Digital I/O and Analog
Control Cards (1CH and 2CH), RS485
Card, RS232 Card
General
Power Requirements
115/230 VAC± 10%, 47Hz - 63Hz
Operating Temperature
0°C- 40°C
Storage Temperature
-10°C- 70°C
1
With sense terminal connected.
2
Maximum time required for the output voltage to change from 1% to 99% or
vice versa following the receipt of VOLTage or VSET command via direct
GPIB or USB interface.
3
Models 9171 – 9183: Less than 50 μs for output to recover to within 15 mV
following a change in output current from full load to half load or vice versa.
Model 9184: Less than 100 μs for output to recover to within 50 mV following
a change in output current from full load to half load or vice versa.
Model9185: Less than 100 μs for output to recover to within 120 mV following
a change in output current from full load to half load or vice versa.
4
Average time for output to start to drop after OVP/OCP condition occurs.
5
Digital I/O Analog Control Card Accuracy:±1%.
To ensure the most current version of this manual, please download the
For current up-to-date product information, please visit