Cmode?/cmode2 – B&K Precision 9171-9174 - Manual User Manual
Page 154

142
CMODE?/CMODE2?
CPV/CPV2
Description:
Configures/Queries the VSET voltage setting of the
selected power supply. See
VOLTage/VOLT2command
for similar syntax.
CPV2 is for dual channel models only.
Example:
CPV 15.698
Sets the selected power supply’s VSET voltage setting
to 15.698 V.
CPV2?
Queries the selected power supply’s second channel
VSET voltage setting.
CMV?/CMV2?
Description:
Queries the measured/readback voltage output value of
the selected power supply. See
VOUT?/VOUT2?
Command for similar syntax.
CMV2? is for dual channel
models only.
Query:
CMV?
Return String:
1.234 V
The selected power supply has a measured output
voltage of 1.234 V.
CPC/CPC2
Description:
Configures/Queries the ISET current setting of the
selected power supply. See
CURRent/CURR2
command for similar syntax.
CPC2 is for dual channel
models only.
Example:
CPC 3.123
Sets the selected power supply’s ISET current setting to
3.123 A.
CPC2?
Queries the selected power supply’s second channel
ISET current setting.
CMC?/CMC2?