B&K Precision 9171-9174 - Manual User Manual
Page 145

133
VOLTage/VOLT2
Note:
VOLT2 command is for dual channel models only.
Description:
Configures/Queries the VSET voltage setting. For dual
channel models, use VOLT2 command for channel 2.
Syntax:
VOLTage
VOLT2
VOLTage?
VOLT2?
Example:
VOLT2 12.000
Sets the second channel VSET voltage to 12.000 V on
a dual channel model.
Query:
VOLT?
Return String:
12.000
Format:
VOUT?/VOUT2?
Note:
VOUT2 command is for dual channel models only.
Description:
Queries the measured/readback voltage output value.
For dual channel models, use VOUT2 command for
channel 2.
Syntax:
VOUT?
VOUT2?
Example:
VOUT?
Return String:
10.002
Output voltage measured is 10.002 V.
Format:
VSET/VSET2
Description:
This command is the same as VOLTage/VOLT2
command. See VOLTage/VOLT2 for details.
Example:
VSET?
VSET 12.345
Format: