beautypg.com

Low current mode – B&K Precision 9171-9174 - Manual User Manual

Page 76

background image

64

With LED mode ON (enabled), the power supply can minimize or
eliminate any inrush current from turning the output ON, which in
turn will minimize damage or life of the LEDs under test.

Note:For LED mode to function correctly, the output must be turned

OFF when connecting between the power supply and the LEDs

under test. Turn ON the output after LED mode is enabled and

all other settings are configured.

WARNING:

For models 9184 and 9185, Low Current MODE

must be set to OFF when using LED mode. If both

are ON, the supply may produce inrush current.


Low Current Mode

Available on models 9184 and 9185 only.
Low current mode is a unique function that enables the power
supply to minimize voltage rise times when operating with low
current (< 1 A) output with a high voltage change.

To enable Low current mode, follow these steps:

1. Press , then to enter

OUTPUT SETTING. Press

to select

Low Current MODE.

Menu

2

6