beautypg.com

Remove the nt6d11ab, nt6d11ae, nt6d11af dch, Procedure 2 – Nortel Networks NN43001-301 User Manual

Page 86

background image

86

DCH installation

5

Install the DCHI card into the assigned shelf and slot.

6

Connect DCHI port J2 to the NT8D72AB or NT8D72BA PRI port J5
with a QCAD328A cable.

7

Set faceplate toggle switch to ENABLE.

8

Coordinate the start-up and verification of the DCHI with the start-up
of the PRI.

9

Enable the DCHI card using LD 96, command ENL DCHI N.

—End—

Remove the NT6D11AB, NT6D11AE, NT6D11AF DCH

Use

Procedure 2 "Remove the NT6D11AB, NT6D11AE, NT6D11AF DCH"

(page 86)

to remove the NT6D11AB, NT6D11AE, NT6D11AF DCH from

a Large System.

CAUTION

The NT6D11AB, NT6D11AE, NT6D11AF DCH must be software
disabled before it is hardware disabled, or initialization will occur.

Procedure 2

Remove the NT6D11AB, NT6D11AE, NT6D11AF DCH

Step

Action

1

Disable the NT6D11AB, NT6D11AE, NT6D11AF DCHI using LD 96,
command DIS DCHI N.

2

If asynchronous port J1 is enabled, it must also be software disabled,
using LD 37, or initialization will occur.

3

If the circuit pack is being completely removed, not replaced, remove
data from memory.

4

Determine the cabinet and shelf location of the card to be removed.

5

Set faceplate toggle switch to DISABLE.

6

Disconnect NT6D11AB, NT6D11AE, NT6D11AF DCHI cables.

7

Remove NT6D11AB, NT6D11AE, NT6D11AF DCHI card.

8

Pack and store the card.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.