Remove the nt6d11ab, nt6d11ae, nt6d11af dch, Procedure 2 – Nortel Networks NN43001-301 User Manual
Page 86

86
DCH installation
5
Install the DCHI card into the assigned shelf and slot.
6
Connect DCHI port J2 to the NT8D72AB or NT8D72BA PRI port J5
with a QCAD328A cable.
7
Set faceplate toggle switch to ENABLE.
8
Coordinate the start-up and verification of the DCHI with the start-up
of the PRI.
9
Enable the DCHI card using LD 96, command ENL DCHI N.
—End—
Remove the NT6D11AB, NT6D11AE, NT6D11AF DCH
Use
Procedure 2 "Remove the NT6D11AB, NT6D11AE, NT6D11AF DCH"
to remove the NT6D11AB, NT6D11AE, NT6D11AF DCH from
a Large System.
CAUTION
The NT6D11AB, NT6D11AE, NT6D11AF DCH must be software
disabled before it is hardware disabled, or initialization will occur.
Procedure 2
Remove the NT6D11AB, NT6D11AE, NT6D11AF DCH
Step
Action
1
Disable the NT6D11AB, NT6D11AE, NT6D11AF DCHI using LD 96,
command DIS DCHI N.
2
If asynchronous port J1 is enabled, it must also be software disabled,
using LD 37, or initialization will occur.
3
If the circuit pack is being completely removed, not replaced, remove
data from memory.
4
Determine the cabinet and shelf location of the card to be removed.
5
Set faceplate toggle switch to DISABLE.
6
Disconnect NT6D11AB, NT6D11AE, NT6D11AF DCHI cables.
7
Remove NT6D11AB, NT6D11AE, NT6D11AF DCHI card.
8
Pack and store the card.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007