Nortel Networks NN43001-301 User Manual
Page 278

278
2.0 Mb PRI implementation
Prompt
Response
Description
PREF CC3
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
SREF CC3
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
CC4
xx
Card number for Clock Controller 4.
PREF CC4
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
SREF CC4
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
CCAR
0-(15)
Clock Controller Audit Rate. Enter the time (in minutes) between
normal CC audits.
LD 73 - Defining PRI parameters and thresholds
Prompt
Response
Description
REQ
CHG
Change data.
TYPE
PRI2
2.0 Mb PRI.
FEAT
LPTI
Loop timers.
LOOP
X
X is the slot number of the 2.0 Mb PRI card.
MFF
AFF (CRC)
Alternate mode or CRC multiframe mode.
ALRM
(REG) ALT
Default or alternate alarms selected.
G10S
SLP
mc mt oc ot
Slip error count.
where
mc
= Maintenance threshold slip count, 1- (5)-255.
mt
= Maintenance threshold time, default 24 hours.
oc
= Out-of-service threshold slip count, 1-(30)-255.
ot
= Out-of-service threshold time, default 1 hour.
BPV
n1 n2
Bipolar violation error count. Range is 1-(128)-255 for n1,
1-(122)-255 for n2.
where
n1
is multiplied by 16 to obtain the actual count, giving an
actual count range of 16-4080.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.