Nt5d97ad dip switch settings, Table 45 dip switch settings for nt5d97ad – Nortel Networks NN43001-301 User Manual
Page 134

134
NT5D97 Dual-port DTI2/PRI2 installation and removal
NT5D97AD DIP switch settings
The NT5D97 DDP2 card is equipped with 6x2 sets of DIP switches for
trunk parameters settings for port 0 and port 1 respectively. Additionally,
the DDP2 card is equipped with one set of four DIP switches for the Ring
Ground setting. The NT5D97AA/AB has one set of eight DIP switches and
NT5D97AD has two sets of ten DIP switches for the D-channel Handler
parameters setting.
The DIP switches are used for the setting of default values of certain
parameters. Firmware reads the general purpose switches, which sets the
default values accordingly
Table 45
DIP switch settings for NT5D97AD
Card
Trunks
0 and 1
Port 0
Port 1
Trunk 0
Trunk 1
ENB/DSB mounted on the face
plate
S1
Ring Ground
S16
DPNSS
S8
S9
MSDL
S9
TX Mode
S2
S10
S3
S13
S4
S14
LBO Setting
S5
S15
Receiver Interface
S6
S11
General Purpose
S12
S7
Refer to DIP switch locations in
Figure 56 "Dip switches locations for
.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007