Table 43 dch mode and address switch settings – Nortel Networks NN43001-301 User Manual
Page 133

NT5D97AA/AB DIP switch settings
133
Table 43
DCH mode and address switch settings
Switch
Description
S3 switch setting
1-4
D-channel daughterboard address
See table
5-8
For future use
OFF
Table 51 "Ring ground switch for NT5D97AD" (page 137)
shows the possible
selections of the NTBK51AA D-channel.
Table 44
NTBK51AA daughterboard addressselect switch settings
Device
Address
Switch Setting
0
OFF
OFF
OFF
OFF
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
Note 1: The system contains a maximum number of 16 DCHI, MSDL, and DDCH devices. The
Device Addresses are equivalent to the MSDL DNUM designations.
Note 2: Device address 0 is commonly assigned to the System TTYD Monitor.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.