Nortel Networks NN43001-301 User Manual
Page 243
DTI software implementation
243
Prompt
Response
Description
SEZ(R)
abcd
Seize signal (send or receive) for voice or data calls from or
to a non-SL-1.
SEZD(R)
abcd
Seize signal (send or receive) for data calls between SL-1s.
N
If SEZD(R) signal not required.
SEZV(R)
abcd
Seize signal (send or receive) for voice calls.
N
If SEZV(R) signals not required.
P CALL(R)
abcd
(Receive) signal sent during seize by an incoming CO trunk.
TIME
ON OFF
Length of pulse time on, and time off.
(default 2 seconds on, 8 seconds off)
SEZA(S)
abcd
Seize signal acknowledgment (send).
N
If SEZA(S) signal not required.
P WNKS(S)
abcd
Wink start (corresponds to a pulsed seize acknowledgment).
Prompted when SEZA(S) not required.
N
If WNKS(S) signal not required.
TIME
10-(220)-630
Time for WNKS(S) signal in milliseconds.
P DIGT(R)
abcd
(Receive) decadic pulses.
N
If DIGT(R) not required.
NRCV(S)
abcd
Number received signal (send).
N
If NRCV(S) signal not required.
P EOSF(S)
abcd
End of selection free (send).
N
If EOSF(S) not required.
TIME
(100)-150
Time for EOSF(S) in milliseconds.
P EOSB(S)
abcd
End of selection busy (send).
N
If EOSB(S) not required.
TIME
(100)-150
Time for EOSB(S) in milliseconds.
P OPCA(R)
abcd
Operator calling time (receive) signal.
N
If OPCA(R) not required.
TIME
64-(128)-192
Time of OPCA(R) pulse in milliseconds.
REPT
(1)-5
Number of OPCA(R) pulses.
CONN(S)
abcd
Connect send.
CONN(R)
abcd
Connect receive.
P RRC(S)
abcd
Register recall (send) signal. Activated by Malicious Call Trace.
N
If RRC(S) not required.
TIME
10-(100)-150
Time of RRC(S) signal in milliseconds.
P BURS(S)
abcd
Bring up receiver (send). Uses switchhook flash timer for timer.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.