beautypg.com

Table 46 general purpose switches for nt5d97ad, Table 47 tx mode switches for nt5d97ad, Table 48 lbo switches for nt5d97ad – Nortel Networks NN43001-301 User Manual

Page 136

background image

136

NT5D97 Dual-port DTI2/PRI2 installation and removal

Trunk interface switches for NT5D97AD

Trunk 0 switches

Switch S12 gives the MPU information about its environment as shown in

Table 46 "General purpose switches for NT5D97AD" (page 136)

.

Table 46
General purpose switches for NT5D97AD

Switch

Description

S9/S15 Switch Setting

S12_1

Impedance level

OFF - 120 ohm
ON - 75 ohm

S12_2

Spare

For future use

S12_3

Spare

For future use

S12_4

Unit mode

OFF - Unit operates in the DTI2 mode
ON - Unit operates in the PRI2 mode

Switch S2 selects the Transmission mode as shown in

Table 47 "TX mode

switches for NT5D97AD" (page 136)

.

Table 47
TX mode switches for NT5D97AD

TX mode

S2

E1

OFF

Not used

ON

Switch S3, S4, and S5 select LBO function as is

Table 48 "LBO switches

for NT5D97AD" (page 136)

.

Table 48
LBO switches for NT5D97AD

LBO setting

S3

S4

S5

0dB

OFF

OFF

OFF

7.5dB

ON

ON

OFF

15dB

ON

OFF

ON

Switch S6 selects the Receiver interface as in

Table 49 "Receiver interface

switches for NT5D97AD" (page 137)

.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.