Table 46 general purpose switches for nt5d97ad, Table 47 tx mode switches for nt5d97ad, Table 48 lbo switches for nt5d97ad – Nortel Networks NN43001-301 User Manual
Page 136
136
NT5D97 Dual-port DTI2/PRI2 installation and removal
Trunk interface switches for NT5D97AD
Trunk 0 switches
Switch S12 gives the MPU information about its environment as shown in
Table 46 "General purpose switches for NT5D97AD" (page 136)
.
Table 46
General purpose switches for NT5D97AD
Switch
Description
S9/S15 Switch Setting
S12_1
Impedance level
OFF - 120 ohm
ON - 75 ohm
S12_2
Spare
For future use
S12_3
Spare
For future use
S12_4
Unit mode
OFF - Unit operates in the DTI2 mode
ON - Unit operates in the PRI2 mode
Switch S2 selects the Transmission mode as shown in
switches for NT5D97AD" (page 136)
Table 47
TX mode switches for NT5D97AD
TX mode
S2
E1
OFF
Not used
ON
Switch S3, S4, and S5 select LBO function as is
Table 48
LBO switches for NT5D97AD
LBO setting
S3
S4
S5
0dB
OFF
OFF
OFF
7.5dB
ON
ON
OFF
15dB
ON
OFF
ON
Switch S6 selects the Receiver interface as in
switches for NT5D97AD" (page 137)
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.