Clock Controller description and installation
16
Insert the replacement card into the selected slot and hook the
locking devices.
17
Connect the reference cables (J1 and J2) and the clock-to-clock
cable (J3) to the replacement card.
18
Set the ENB/DIS switch to ENB on the replacement card.
19
Disable the software and enable the card. At the prompt, enter:
LD 60
DID CC x
Disable clock controller card, where x=0 or 1
ENL CC x
Enable clock controller card, where x=0 or 1
20
Verify that the card is active. At the prompt, enter:
SSCK x
Get status of system clock, where x=0 or 1
****
Exit the overlay
Note: Wait two minutes before proceeding to next step.
21
Activate the new card and verify that it is active. At the prompt enter:
LD60
SWCK
Switch system clock from active to standby
SSCK x
Get status of system clock, where x = 0 or 1
TRCK PCK
Track primary clock, where x = 0 or 1
RCNT
Reset alarm counters of all digital cards
****
Exit the overlay
22
Set the clock source to the status it was in before the replacement
procedure.
23
Verify clock switchover and tracking. At the prompt, enter:
SWCK
Switch system clock from active to standby
SSCK x
Get status of system clock, where x = 0 or 1
****
Exit the overlay