Cable requirements – Nortel Networks NN43001-301 User Manual
Page 102

102
NT8D72 and QPC720 PRI card installation
Note 2: This chapter includes instructions for installing an additional
network shelf on a system (when no vacant Network slots are available
to install PRI packs, additional network shelves can replace Intelligent
Peripheral Equipment shelves located on the rear of the Common
Equipment or Disk shelves). Refer to
"Install an additional network
Cable requirements
Shielded 22 AWG (0.644 mm) cables are recommended for connecting
the PRI to the crossconnect point. This cable consists of two twisted-pair
conductors.
The transmit and the receive pairs must be enclosed in a polyvinyl jacket.
This type of cable is commonly referred to as "6-conductor" cable. The
cable should be grounded at the crossconnect point.
In addition to twisted-pair conductors, 75-ohm coaxial cable can also be
used to provide connection to the office repeater or line terminating unit
(LTU).
For manufacture cables of lengths different than those of the standard
cables provided, see "Nonstandard cables" on
For the 2.0 Mb NT8D72 PRI card, see
cabling) on Half and Single Group systems without an echo canceller"
(page 103)
,
Figure 42 "NT8D72 (Half Group cabling) for Half and Single
Group systems, with an echo canceller" (page 104)
,
(Single Group cabling) for Half and Single Group systems, without an echo
canceller" (page 105)
, and
Figure 44 "NT8D72 (Single Group cabling) for
Half and Single Group systems, with an echo canceller" (page 106)
for Half
Group and Single Group cabling arrangements applying to the system; also,
refer to
Table 52 "NTBK51AA DCH switches for NT5D97AD" (page 138)
For the 2.0 NT8D72 on a Multi Group arrangement, see
(Multi Group cabling) for Multi Group systems without an echo canceller"
(page 107)
and
Figure 46 "NT8D72 (Multi Group cabling) for Multi Group
systems with an echo canceller" (page 108)
; also refer to
for the NT8D72 PRI card for Multi Group systems" (page 116)
.
For the 1.5 Mb QPC720 PRI card on Half Group and Single Group systems,
see
Figure 47 "QPC720 (Half Group cabling) for Multi Group systems
without an echo canceller" (page 109)
cabling) for Multi Group systems with an echo canceller" (page 110)
49 "QPC720 (Single Group cabling) for Multi Group systems without an
echo canceller" (page 111)
, also, refer to
Table 31 "Cable for the QPC720
PRI card for Half and Multi Group systems" (page 117)
. For the QPC720 on
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.