DTI software implementation
253
Prompt
Response
Description
PREF CC1
xx
Primary Reference DTI/PRI loop for Clock controller one.
SREF CC1
xx
Primary Reference DTI/PRI loop for Clock controller one.
CC2
xx
Card number for Clock Controller 2.
PREF CC2
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
SREF CC2
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
CC3
xx
Card number for Clock Controller 3.
PREF CC3
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
SREF CC3
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
CC4
xx
Card number for Clock Controller 4.
PREF CC4
xx
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
CCGD
0-(15)-1440
Clock controller free run guard time in minutes.
CCAR
0-(15)
Clock controller audit rate. The time, in minutes, between normal
CC audits. Only programmable on units equipped with 2-Mb DTI.
Note 1: The clock controller prompts only appear for clocks
which are valid for the machine type being configured. The
prompts only appear if the system is in a valid state for the
definition of the 2.0 Mb DTI clock controller data that is, the DTI
clock references must be unused or in a free-run mode.
Note 2: Before programming clock controller references, the
QPC775 clock controller card(s) must be plugged in, and the
switches on the system’s QPC441 3 Port Extender must be
appropriately set. Otherwise, the PREF and SREF prompts are
not given.
LD 16 - Configuring the service routes
Prompt
Response
Description
REQ
NEW
CHG
Add or Change Route data block.
TYPE
RDB
Route data block.
CUST
xx
Customer number, as defined in LD 15
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007