Table 41 trunk interface impedance switch settings, Table 42 ring ground switch settings – Nortel Networks NN43001-301 User Manual
Page 132
132
NT5D97 Dual-port DTI2/PRI2 installation and removal
Receiver impedance
A per-trunk set of four DIP switches (S8/S14 provides selection between
75 or 120 ohm values. Refer to
Table 41 "Trunk interface impedance switch
.
Table 41
Trunk interface impedance switch settings
Description
S8/S14 switch setting
75 ohm
OFF
OFF
ON
OFF
120 ohm
OFF
OFF
OFF
ON
Ring ground switches for NT5D97AA/AB
A set of four DIP switches (S2) selects which Ring lines are connected to
the ground. Refer to
Table 48 "LBO switches for NT5D97AD" (page 136)
Table 42
Ring ground switch settings
Switch
Description
S2 switch settings
1
Trunk 0 Transit
OFF-Ring line is not grounded
ON- Ring line is grounded
2
Trunk 0 Receive
OFF-Ring line is not grounded
ON- Ring line is grounded
3
Trunk 1 Transmit
OFF-Ring line is not grounded
ON- Ring line is grounded
4
Trunk 1 Receive
OFF-Ring line is not grounded
ON- Ring line is grounded
DCH Address select switch for NTBK51AA daughter board for
NT5D97AA/AB
In case of an onboard NTBK51AA D-channel daughterboard, a set of four
switches (S3) provide the daughterboard address. Refer to
Note: Switch 8 of S3 (S3-8) does not require a switch setting to
select between the onboard NTBK51AA D-channel daughterboard
and an external DCHI/MSDL. The NT5D97 detects when the onboard
NTBK51AA D-channel daughterboard is used.