beautypg.com

Nortel Networks NN43001-301 User Manual

Page 252

background image

252

2.0 Mb DTI implementation

Prompt

Response

Description

GP2

T2 mt dt ct ot

Group 2 error thresholds.
This is the maximum amount of time that can occur before
software checks the associated thresholds of 120 to 32640
msec and rounds it to the closest multiple of 128 msec. T2 error
count values are in the range 1-(20)-255. NC = Error count
values are in the range 1-255.
mt = Maintenance threshold time (MNT).
dt = No new data calls threshold time (NNDC).
ct = No new calls threshold time (NNC).
ot = Out of service threshold time (OOS).

Note: The following requirements must be met for this input: mt
= >dt = >ct = >ot.

FRFW

YES (NO)

This 2.0 Mb DTI card is (is not) equipped with special Firmware
for France.

LD 73 - Defining the 2.0 Mb DTI system timers

Prompt

Response

Description

REQ

NEW
CHG

Add or Change Digital Trunk Interface data block.

TYPE

DTI2

2.0 Mb DTI.

FEAT

SYTI

Change the switch timers and counters for 2.0 Mb DTI.

There is only one such block per switch.

MAND

0-(15)-1440

Maintenance guard time in minutes.

NCSD

0-(15)-1440
1S-59S

New call suppression guard time in minutes and seconds.

OSGD

0-(15)-1440

Out-of-service guard time in minutes.

OOSC

0-(5)-127

Out-of-service occurrences since midnight (DTI disabled).

PERS

0-(100)-254

Persistence timer in milliseconds for far-end problems.

DBNC

(10)-32

Debounce timer in milliseconds.

CCO

xx

Card slot number for Clock Controller 0.

No change for defaults.

X

To remove clock controller data.

PREF CCO

xx

Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet

SREF CCO

xx

Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet

CC1

xx

Card number for Clock Controller 1.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.