2.0 Mb DTI implementation
Prompt
Response
Description
GP2
T2 mt dt ct ot
Group 2 error thresholds.
This is the maximum amount of time that can occur before
software checks the associated thresholds of 120 to 32640
msec and rounds it to the closest multiple of 128 msec. T2 error
count values are in the range 1-(20)-255. NC = Error count
values are in the range 1-255.
mt = Maintenance threshold time (MNT).
dt = No new data calls threshold time (NNDC).
ct = No new calls threshold time (NNC).
ot = Out of service threshold time (OOS).
Note: The following requirements must be met for this input: mt
= >dt = >ct = >ot.
FRFW
YES (NO)
This 2.0 Mb DTI card is (is not) equipped with special Firmware
for France.
LD 73 - Defining the 2.0 Mb DTI system timers
Prompt
Response
Description
REQ
NEW
CHG
Add or Change Digital Trunk Interface data block.
TYPE
DTI2
2.0 Mb DTI.
FEAT
SYTI
Change the switch timers and counters for 2.0 Mb DTI.
There is only one such block per switch.
MAND
0-(15)-1440
Maintenance guard time in minutes.
NCSD
0-(15)-1440
1S-59S
New call suppression guard time in minutes and seconds.
OSGD
0-(15)-1440
Out-of-service guard time in minutes.
OOSC
0-(5)-127
Out-of-service occurrences since midnight (DTI disabled).
PERS
0-(100)-254
Persistence timer in milliseconds for far-end problems.
DBNC
(10)-32
Debounce timer in milliseconds.
CCO
xx
Card slot number for Clock Controller 0.
No change for defaults.
X
To remove clock controller data.
PREF CCO
xx
Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet
SREF CCO
xx
Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet
CC1
xx
Card number for Clock Controller 1.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.