2.0 Mb PRI implementation
Prompt
Response
Description
PERS
ttt
Persistence Timer for Group II problems.
Enter 0-256 msec in increments of 2 msec. Default is 50
(=100ms).
CLRS
ttt
Clearance Timer for Group II problems. Enter 0 - 256 msec in
increments of 2 msec. Default is 50 (=100ms).
OOSC
nnn
Out-of-Service Counter.
Range for nnn of 0-255 with a default of 5.
LD 73 - Changing trunk pad category values
Prompt
Response
Description
REQ
CHG
Change data.
TYPE
PRI2
2.0 Mb PRI.
FEAT
PADS
PDCA
#
PAD table-0 is default and is hard coded.
The following prompts define the pad levels.
The receiving pad code is r and the transmission pad code is t. These entries have the range 0-15.
The pad values (in decibels) relating to these codes are shown after this table.
ONP
r t
On-premises extension.
DSET
r t
Meridian Digital set.
Prompted only if the 2.0 Mb Gateway feature is equipped.
OPX
r t
Off-premises extension.
DTT
r t
Digital TIE trunks.
SDTT
r t
Digital Satellite TIE trunks.
NTC
r t
Nontransmission compensated.
TRC
r t
Transmission compensated.
DCO
r t
Digital COT, FEX, WAT, and DID trunks.
VNL
r t
Via Net Loss.
DTO
r t
2.0 Mb PRI2 digital TOLL office trunks.
ACO
r t
Analog CO or WATS trunks.
AFX
r t
Analog FEX trunks.
ADD
r t
Analog DID trunks.
SATT
r t
Analog satellite TIE trunks.
ATO
r t
Analog TOLL office trunks.
PRI2
r t
2.0 Mb PRI trunk.
Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=2.0 Mb PRI.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007