NT5D12 switch settings

147

Table 59
Ring ground switch settings

Switch

Description

S2 Switch Setting

1

Trunk 0 Transmit

OFF - Ring line is not grounded

ON - Ring line is grounded

2

Trunk 0 Receive

OFF - Ring line is not grounded

ON - Ring line is grounded

3

Trunk 1 Transmit

OFF - Ring line is not grounded

ON - Ring line is grounded

4

Trunk 1 Receive

OFF - Ring line is not grounded

ON - Ring line is grounded

DCH mode and address select switches

A set of eight DIP switches selects between an onboard NTBK51AA
D-channel daughterboard and an external MSDL/DCHI card. In the case
of an onboard NTBK51AA D-channel daughterboard, four of the switches
provide the daughterboard address. See

Table 60 "DCH mode and address

select switch settings" (page 147)

.

Table 60
DCH mode and address select switch settings

Switch

Description

S3 Switch Setting

1-4

D-channel daughterb
oard
Address

See

Table 61 "NTBK51AA daughterboard

address select switch settings" (page 148)

5-7

For future use.

OFF

8

External DCH or
Onboard DDCH

OFF - MSDL or DCHI card

ON - Onboard DDCH daughterboard

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007