Table 59 ring ground switch settings – Nortel Networks NN43001-301 User Manual
Page 147

NT5D12 switch settings
147
Table 59
Ring ground switch settings
Switch
Description
S2 Switch Setting
1
Trunk 0 Transmit
OFF - Ring line is not grounded
ON - Ring line is grounded
2
Trunk 0 Receive
OFF - Ring line is not grounded
ON - Ring line is grounded
3
Trunk 1 Transmit
OFF - Ring line is not grounded
ON - Ring line is grounded
4
Trunk 1 Receive
OFF - Ring line is not grounded
ON - Ring line is grounded
DCH mode and address select switches
A set of eight DIP switches selects between an onboard NTBK51AA
D-channel daughterboard and an external MSDL/DCHI card. In the case
of an onboard NTBK51AA D-channel daughterboard, four of the switches
provide the daughterboard address. See
Table 60 "DCH mode and address
select switch settings" (page 147)
.
Table 60
DCH mode and address select switch settings
Switch
Description
S3 Switch Setting
1-4
D-channel daughterb
oard
Address
See
Table 61 "NTBK51AA daughterboard
address select switch settings" (page 148)
5-7
For future use.
OFF
8
External DCH or
Onboard DDCH
OFF - MSDL or DCHI card
ON - Onboard DDCH daughterboard
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007