Table 30 "cable – Nortel Networks NN43001-301 User Manual
Page 116
116
NT8D72 and QPC720 PRI card installation
Table 30
Cable for the NT8D72 PRI card for Multi Group systems
Cable
From
Des.
Con.
To
Des.
Con.
Notes
QCAD130
PRI card
J1
Clock contro
ller
CC-0
1
QCAD130
PRI card
J1
Clock contro
ller
CC-0
2
QCAD130
PRI card
J2
Clock contro
ller
CC-1
1
QCAD130
PRI card
J2
Clock contro
ller
CC-1
2
QCAD110
Clock contro
ller
CC-0
J3
Junctor
board
JCTR
J11
3
QCAD110
Clock contro
ller
CC-1
J3
Junctor
board
JCTR
J12
QCAD124
PRI card
J3
Network
4
QCAD328A
PRI card
J5
DCHI card
J2
5
NTND26
PRI card
J5
MSDL
QCAD128
PRI card
J4
I/O Panel
6
QCAD133
I/O Panel
Patch Panel
6
QCAD129
PRI card
J6
I/O Panel
6
RS-232
I/O Panel
Echo Cance
ller
RS-232
PRI card
J6
Echo Cance
ller
7
Note 1: Only when primary clock source.
Note 2: Only when secondary clock source.
Note 3: multigroup junctor board connection.
Note 4: Run to connector on network pack.
Note 5: Run directly to DCHI card.
Note 6: Run by means of cabinet I/O panel to CSU, echo canceller, or cross connect terminal.
Note 7: Run by means of cabinet I/O panel to crossconnect terminal or echo canceller from non
shielded system.
Note 8: No additional cabling is required for multiple PRIs. The D-channel is associated through
software in LD17, prompt PRI.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.