The NTRB21 card is installed only in the Media Gateway. It is not supported
in the Media Gateway Expansion.

Procedure 25

Inserting the NTRB21 TMDI card

Step

Action

1

Check for available card slots in the base cabinet and print the
configuration record to determine which slots can be used. To do
this, enter the following command in LD 22:

PRT CFN

in LD 22

2

If in PRI mode, enter the following command in LD 96 to software
disable the D-channel:

DIS DCH x

where x is the DCH port number that was assigned in LD 17.

3

If the Clock Controller is enabled, enter the following command in LD
60 to software disable it:

DIS CC 0

4

Hold the NTRB21 by the lock latch, unlock the latch, and slide the
card into the cabinet.

Note: Refer to

Table 74 "Shelf slot assignments for NTRB21,

NTAK09, and NTAK20" (page 202)

to determine the correct slot

in which to insert the card.

5

Enter the following command in LD 96 to enable the TMDI card:

ENL TMDI x ALL

where x is the NTRB21 TMDI card number (DLOP). The card
number associated with an NTRB21 TMDI card is based on the
slot in which the card is installed.

6

Within about 30 seconds, the D-channel layer 3 should be
established. To confirm, enter the following command in LD 96 to
request the current status of the D-channel:

STAT DCH (N)

The system response is:

DCH N EST OPER

This means that the D-channel is established and operational.

—End—

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.