Upgrade to an NTRB53 Clock Controller on a Single Group and Multi
Group System

Follow these procedures to replace the existing clock controller with the
NTRB53 Clock Controller on Large Systems.

Note: The NTRB53 Clock Controller cannot be combined with a
QPC775 or a QPC471 card in one system.

Procedure 20

Remove old equipment

Step

Action

1

Ensure the clock controller card being removed for dual core
systems is on the inactive core. If you need to switch cores go to
LD 135 and enter:

LD 135

SCPU

Switch cores

****

Exit the overlay

2

Disable the QPC775 or QPC471 Clock Controller card. At the
prompt, enter:

LD 60

Load the program

SSCK x

Get status of system clock where x = 0 or 1

Switch clocks if the clock is active at the prompt, enter:

SWCK

Switch system clock from active to standby

SSCK x

Get status of system clock where x = 0 or 1

Ensure the other clock controller is active and in the free run mode. At
the prompt, enter:

SSCK x

Get status of system clock where x = 0 or 1

TRCK
FRUN

Set clock controller tracking to free run

3

Disable the clock controller card you are removing. At the prompt,
enter:

DIS CC x

Disable system clock controller where x = 0 or 1