Upgrade to an NTRB53 Clock Controller on a Single Group and Multi
Group System
Follow these procedures to replace the existing clock controller with the
NTRB53 Clock Controller on Large Systems.
Note: The NTRB53 Clock Controller cannot be combined with a
QPC775 or a QPC471 card in one system.
Procedure 20
Remove old equipment
Step
Action
1
Ensure the clock controller card being removed for dual core
systems is on the inactive core. If you need to switch cores go to
LD 135 and enter:
LD 135
SCPU
Switch cores
****
Exit the overlay
2
Disable the QPC775 or QPC471 Clock Controller card. At the
prompt, enter:
LD 60
Load the program
SSCK x
Get status of system clock where x = 0 or 1
Switch clocks if the clock is active at the prompt, enter:
SWCK
Switch system clock from active to standby
SSCK x
Get status of system clock where x = 0 or 1
Ensure the other clock controller is active and in the free run mode. At
the prompt, enter:
SSCK x
Get status of system clock where x = 0 or 1
TRCK
FRUN
Set clock controller tracking to free run
3
Disable the clock controller card you are removing. At the prompt,
enter:
DIS CC x
Disable system clock controller where x = 0 or 1
Nortel Communication Server 1000