beautypg.com

Procedure 19, System – Nortel Networks NN43001-301 User Manual

Page 173

background image

Installation procedures

173

TRCK

PCK

(for primary)

SCLK

(for secondary)

FRUN

(for free-run)

14

Issue the status check command, SSCK.

Note: In order for the clock enhancement feature in the clock
controller (NTRB53) to be fully functional, the user must issue a
manual INI to activate the clock enhancement feature.

—End—

Install or replace a Clock Controller on a Single Group and Multi Group
System

Procedure 19 "Install a Clock Controller on a Single Group and Multi Group
System" (page 173)

outlines the steps to install a clock controller on Single

Group and Multi Group systems.

Procedure 19

Install a Clock Controller on a Single Group and Multi Group System

Step

Action

1

Unpack and inspect the circuit card.

2

Determine the cabinet and shelf location. Refer to

Table 64 "Clock

Controller shelves and slots" (page 169)

.

3

Set the clock controller switch. Refer to

Table 65 "Clock Controller

switch settings for QPC471 vintage H" (page 169)

,

Table 66 "Clock

Controller switch settings for QPC775" (page 170)

, or on

Table 65

"Clock Controller switch settings for QPC471 vintage H" (page 169)

.

4

Set the ENL/DIS toggle switch to DIS (disable).

5

If replacing a clock controller, do the following:

Perform a status check on the clock with the SSCK command in
LD 60. The new controller should have the same status.

Use LD 135 to STAT the CPU and switch if necessary

Disable the old card using LD 60.

Note 1: Do not disable an active clock or a clock associated
with an active CPU.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.