beautypg.com

Nortel Networks NN43001-301 User Manual

Page 291

background image

ISL software implementation

291

Prompt

Response

Description

N201

4(260)

Maximum number of octets in information
field.

K

1-(7)-32

Maximum number of outstanding
unacknowledged frames (NAKS).

LD 15 - Enable the ISDN option

Prompt

Response

Description

REQ:

NEW
CHG

Add new data.
Change existing data.

TYPE:

NET

Networking data.

CUST

0-99

Customer number
Range for Large System, Call Server 1000E, and Media
Gateway
1000E

0-31

Range for Small System, Media Gateway 1000B,

ISDN

YES

Customer is equipped with ISDN.

PNI

1-32700

Customer private network identifier. MUST be unique to
this customer in the private network. Used as part of the
setup message for feature operation such as Network Ring
Again and Network ACD.

HNPA

NPA

Telephone area code for this system. Sent as part of setup
message as CLID.

HNXX

NXX

Telephone local exchange code for this system. Sent as
part of setup message for calling line identification.

HLOC

XXX

Home location code (NARS).

LSC

1-9999

One to four digit Local Steering Code established in the
Coordinated Dialing Plan (CDP). The LSC prompt is
required for Calling Line ID and Network ACD.

AC2

Access Code 2. Enter call types (type of number) that use
access code 2. Multiple responses are permitted. This
prompt only appears on NARS equipped systems. If a call
type is not entered here, it is automatically defaulted to
access code 1.

NPA

E.164 National.

NXX

E.164 Subscriber.

INTL

International.

SPN

Special Number.

LOC

Location Code.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.