Nortel Networks NN43001-301 User Manual
Page 291
ISL software implementation
291
Prompt
Response
Description
N201
4(260)
Maximum number of octets in information
field.
K
1-(7)-32
Maximum number of outstanding
unacknowledged frames (NAKS).
LD 15 - Enable the ISDN option
Prompt
Response
Description
REQ:
NEW
CHG
Add new data.
Change existing data.
TYPE:
NET
Networking data.
CUST
0-99
Customer number
Range for Large System, Call Server 1000E, and Media
Gateway
1000E
0-31
Range for Small System, Media Gateway 1000B,
ISDN
YES
Customer is equipped with ISDN.
PNI
1-32700
Customer private network identifier. MUST be unique to
this customer in the private network. Used as part of the
setup message for feature operation such as Network Ring
Again and Network ACD.
HNPA
NPA
Telephone area code for this system. Sent as part of setup
message as CLID.
HNXX
NXX
Telephone local exchange code for this system. Sent as
part of setup message for calling line identification.
HLOC
XXX
Home location code (NARS).
LSC
1-9999
One to four digit Local Steering Code established in the
Coordinated Dialing Plan (CDP). The LSC prompt is
required for Calling Line ID and Network ACD.
AC2
Access Code 2. Enter call types (type of number) that use
access code 2. Multiple responses are permitted. This
prompt only appears on NARS equipped systems. If a call
type is not entered here, it is automatically defaulted to
access code 1.
NPA
E.164 National.
NXX
E.164 Subscriber.
INTL
International.
SPN
Special Number.
LOC
Location Code.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.