NT5D97 Dual-port DTI2/PRI2 installation and removal
Consider the following when configuring the NT5D97 DDP2 card:
•
The system software allows four ports to be defined for the NT6D80
MSDL. The DDCH (NTBK51AA) card has only two ports, 0 and 1;
therefore, ports 2 and 3 must not be defined when using the NTBK51AA.
•
Port 0 of the NTBK51AA can only be defined to work with Loop 0 of the
NT5D97 DDP2 card, and Port 1 of the NTBK51AA can only be defined
to work with Loop 1 of the NT5D97. This relationship must be reflected
when configuring a new DCH in LD 17 (in response to the DCHL prompt,
enter either 0 or 1 when specifying the loop number used by the DCH).
•
You cannot define one of the DDP2 loops for the NTBK51AA DDCH,
and the other loop for the NT6D11AF, NT5K75AA, and NT5K35AA DCH
card or the NT6D80 MSDL.
•
When configuring the NT5D97 DDP2 in DTI2 outgoing dial pulse mode,
a Digit Outpulsing patch is required.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5