beautypg.com

Figure 69 msdl/isl settings, Shared mode – Nortel Networks NN43001-301 User Manual

Page 182

background image

182

ISL installation

Figure 69
MSDL/ISL settings

Shared mode

In shared mode, the D-channel is provided by the DCHI or MSDL card and
PRI. The hardware configuration is basically the same as the ISDN PRI
D-channel. See

Figure 70 "ISL in shared mode" (page 183)

.

Shared mode is established through service change in LD17, prompt USR,
with the response SHA.

In the shared mode, the DCH can share signaling for no more than 382 (T1)
or 480 (E1) trunks, including digital and analog.

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning

NN43001-301

02.03

Standard

Release 5.5

7 December 2007

Copyright © 2003-2007, Nortel Networks

.