Table 25 port 1 mode selection, Table 26 port address switch settings for isdn, Table 25 "port 1 mode selection – Nortel Networks NN43001-301 User Manual
Page 84

84
DCH installation
Table 25
Port 1 mode selection
Port Mode
Switch Setting
SW2.1
SW2.2
Synchronous, D-channel, standard addressing
Note: THIS SELECTION MUST BE MADE FOR
ISDN.
0
0
Synchronous, D-channel, expanded addressing
0
1
Not used
1
0
Port disabled
1
1
Port address switch settings
Port address switch settings in the standard mode, for ISDN
Table 26 "Port address switch settings for ISDN" (page 84)
depicts the port
address switch settings that apply to SW1 or SW2, the D-channel port,
for ISDN mode.
Table 26
Port address switch settings for ISDN
Port Address
Switch Setting
Half Group No.
Device No.
S3
S4
S5
S6
S7
S8
S9
S10
0
0
0
0
0
0
0
0
x
1
0
0
0
0
0
0
1
x
2
0
0
0
0
0
1
0
x
3
0
0
0
0
0
1
1
x
4
0
0
0
0
1
0
0
x
5
0
0
0
0
1
0
1
x
6
0
0
0
0
1
1
0
x
7
0
0
0
0
1
1
1
x
8
0
0
0
1
0
0
0
x
9
0
0
0
1
0
0
1
x
10
0
0
0
1
0
1
0
x
11
0
0
0
1
0
1
1
x
12
0
0
0
1
1
0
0
x
13
0
0
0
1
1
0
1
x
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.