Table 56 – Nortel Networks NN43001-301 User Manual
Page 146

146
NT5D12 Dual-port DTI/PRI card installation
Table 56
Trunk interface transmission mode switch settings
Description
S4/S10 Switch Setting
For future use.
OFF
T1
ON
Line Build Out
A per-trunk set of three switches provides a selection between 0, 7.5 or 15
dB values. See
Table 57 "Trunk interface line build out switch settings"
Table 57
Trunk interface line build out switch settings
Description
Switch Setting
S5/S11
S6/S12
S7/S13
0 dB
OFF
OFF
OFF
7.5 dB
ON
ON
OFF
15 dB
ON
OFF
ON
Receiver Impedance
A per trunk set of four DIP switches provides a selection between 75, 100
or 120
values. See
Table 58 "Trunk interface receiver impedance switch
.
Table 58
Trunk interface receiver impedance switch settings
Description
S8/S14 Switch Setting
75
OFF
OFF
ON
OFF
100
ON
OFF
OFF
ON
120
OFF
OFF
OFF
ON
Ring ground switches
A set of four DIP switches selects which Ring lines are connected to the
ground. See
Table 59 "Ring ground switch settings" (page 147)
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.