Table 82 ntak02 switch setting, Table 83 ntak02 jumper settings, Procedure 37 installing isl hardware – Nortel Networks NN43001-301 User Manual
Page 230: Procedure 37, Installing isl hardware

230
1.5 Mb ISL implementation
The NTAK02 connects to a modem via the NTAK19BA four-port cable. Only
ports 1 and 3 are available for use as DCHIs.
Procedure 37
Installing ISL hardware
Step
Action
1
Set option switches/jumpers on the NTAK02 card as shown in
82 "NTAK02 switch setting" (page 230)
and
for mode of operation (RS232 or RS422
and DTE or DCE.)
Table 82
NTAK02 switch setting
Port 0
Port 1
SW 1-1
SW 1-2
SDI
DCH
OFF
OFF
SDI
DPNSS
OFF
ON
—
ESDI
ON
ON
Port 2
Port 3
SW 1-3
SW 1-4
SDI
DCH
OFF
OFF
SDI
DPNSS
OFF
ON
—
ESDI
ON
ON
Table 83
NTAK02 jumper settings
Unit
Jumper location
Strap for DTE
Strap for DCE
Unit 0
J10
C - B
B - A
Unit 1
J7
J6
C - B
C - B
B - A
B - A
Unit 2
J5
C - B
B - A
Unit 3
J4
J3
C - B
C - B
B - A
B - A
Unit
Jumper location
RS422
RS232
Unit 0
—
—
—
Unit 1
J9
J8
C - B
C - B
B - A
B - A
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301
02.03
Standard
Release 5.5
7 December 2007
Copyright © 2003-2007, Nortel Networks
.