77

SMC–4000 User Manual

CF (Configure Messages)

[Configuration]

DESCRIPTION:

Sets the controller’s default port for unsolicited messages. By default, the

SMC–4000

controller will send

unsolicited responses to the RS-232 serial port. An unsolicited message is one generated in the controller,
i.e.; a program fault message or a message resulting from the

MG (Message)

command with no port

designation specified. Messages originating in the controller can be forced to a specific port–

See the MG

(Message) command

.

ARGUMENTS:

CF n

where

n is A through H for Ethernet handles 1 thru 8, S for serial port.

USAGE:

OPERAND USAGE:

_CF will return the current port selected for unsolicited responses from the controller. The _CF will return
a decimal value of the ASCII code.

EXAMPLES:

While Moving

Yes

Default Value

83 (“S”)

In a Program

Yes

Default Format

Decimal

representation

Command Line

Yes

CFA

Select Ethernet handle A to return unsolicited

responses.

MG_CF

Interrogate configuration

:65.000

Response from _CF showing handle A as

default port. 65 is the ASCII value for “A”.