Mr (motion reverse), Trippoint – Yaskawa SMC–4000 User Manual
Page 170
160
SMC–4000 User Manual
MR (Motion Reverse)
[Trippoint]
DESCRIPTION:
The MR command is a trippoint used to control the timing of events. This command will hold up the
execution of the following command until the specified motor moves backward and crosses the position
specified. The units of the command are in quadrature counts. The MR command can also be used when the
encoder is the master and not under servo control.
ARGUMENTS: MR x, y, z, w or MRX=x or MR a, b, c, d where
x, y z, w, or a, b, c, d are signed integers
USAGE:
RELATED COMMANDS:
EXAMPLES:
HINT:
MR command accuracy is the number of counts that occur in 2 msec. Multiply speed by 2 msec to obtain maximum
error. MR tests for absolute position. The MR command can also be used when the specified motor is driven
externally.
While Moving
Yes
Minimum Value
-2147483648
In a Program
Yes
Maximum Value
2147483647
Command Line
Yes
Default Value
---
Can be Interrogated
No
Default Format
---
Used as an Operand
No
Virtual Axis
No
#TEST Program
B
DP0 Define
zero
JG 1000
Jog mode (speed of 1000 counts/sec)
BG
Begin move
MR -3000
After passing the position -3000
V1=_TP
Assign current position to variable V1.
MG "Position is", V1
Print Message
ST
Stop
EN
End of Program